Pomegranate Systems Power Module

Digital Power Module with high resolution current integration, 5V/2A supply with power monitoring, single UAVCAN v0 CANbus interface, and an RGB status LED.

Detailed setup, configuration, and troubleshooting information can be found on the manufacturer's device home page.

Specifications

  • Input Voltage: 6-26V (2-6S)

  • Max Continuous Current:

    • Benchtop: 40A

    • Forced Cooling: 100A

  • Max 5V Output Current: 2A

  • Voltage Resolution: 0.04 ΔV

  • Current Resolution:

    • Primary / Battery Bus: 0.02 ΔA

    • 5V bus: 0.001 ΔA

  • CANbus Termination: Electronic (on by default)

  • MCU: STM32 F302K8U

  • Firmware: Open Source

  • Electrical Interface:

    • Power: Solder pads or XT60PW (right angle, board-mounted connectors)

    • CANbus Dual JST GH-4 (standard UAVCAN micro-connector)

    • I2C / Serial: JST GH-5

    • 5V Output: Solder pads or CANbus / I2C connectors

  • Device Mass:

    • Without Connectors: 9g

    • With XT60PW Connectors: 16g

Configuration

  1. Enable UAVCAN by setting the UAVCAN_ENABLE parameter to 2 (Sensors Automatic Config) or 3.

  2. Set the following module parameters using the Mavlink console:

    • Battery capacity in mAh: battery_capacity_mAh

    • Battery voltage when full: battery_full_V,

    • Battery voltage when empty: battery_empty_V

    • Turn on current integration: enable_current_track

    • (optional) Turn Off CANbus termination resistor :enable_can_term

Example: A Power Module with UAVCAN node id 125 connected to a 3S LiPo with capacity of 5000mAh can be configured with the following commands:

uavcan param set 125 battery_capacity_mAh 5000
uavcan param set 125 battery_full_V 12.5
uavcan param set 125 battery_empty_V 11.2
uavcan param set 125 enable_current_track 1
uavcan param save 125

See device configuration page for a full list of parameters.